출력 전류 범위 | 25 mA to 25A (max.250A) |
---|---|
주파수 범위 | 20 Hz to 200 / 500 kHz / 1 MHz |
정확도 | 0.1 % |
중첩기능 | 최대 5개 장비 병렬연결, 250 A |
Measurement Function | In impedance mode: L, Z, R, Q, D. Not applicable to Rdc, or transformer measurements |
||||||||
Frequency Range | 3255BL 20 Hz to 200 kHz (not compatible with 3265B/25A and 3265BQ/25A) 3255B 20 Hz to 500 kHz 3255BQ 20 Hz to 1 MHz 3260B 20 Hz to 3 MHz (3265BQ/25A) |
||||||||
Compliance Voltage | Maximum compliance votage (<12 kHz) 11 V DC at 0.25 V AC drive level. 10 V compliance at 1 V AC drive level. For f>12 kHz deduct 0.5 V. |
||||||||
Basic Accuracyy | ±1%, Varies with measurement speed, frequency and options chosen. | ||||||||
Measurement Speeds | <td "="" border-top:=" " solid=""> | ||||||||
Input Specification | Universal 90 to 255 V AC, 47 to 63 Hz Input current 9 A rms max. Power factor >0.9 Unit powers up automatically when connected to a powered analyzer. Isolating switch provided |
||||||||
Measurement Connections | 2-terminals measurement via M8 studs. 4-terminal measurement via Kelvin leads and M8 studs. Measurement terminals internally protected by 1.6A fuses against normal inductor back-EMF or accidental disconnection of inductor. Front panel fuses easily replaced. |