출력 전류 범위 | 25 mA to 25A (max.250A) |
---|---|
주파수 범위 | 20 Hz to 200 / 500 kHz / 1 MHz |
정확도 | 0.1 % |
중첩기능 | 최대 5개 장비 병렬연결, 250 A |
Measurement Function | In impedance mode: L, Z, R, Q, D. Not applicable to Rdc, or transformer measurements |
||||||||
Frequency Range | 3255BL 20 Hz to 200 kHz (not compatible with 3265B/25A and 3265BQ/25A) 3255B 20 Hz to 500 kHz 3255BQ 20 Hz to 1 MHz 3260B 20 Hz to 3 MHz (3265BQ/25A) |
||||||||
Compliance Voltage | Maximum compliance votage (<12 kHz) 11 V DC at 0.25 V AC drive level. 10 V compliance at 1 V AC drive level. For f>12 kHz deduct 0.5 V. |
||||||||
Basic Accuracyy | ±1%, Varies with measurement speed, frequency and options chosen. | ||||||||
Measurement Speeds | <td "="" border-top:=" " solid=""> | ||||||||
Input Specification | Universal 90 to 255 V AC, 47 to 63 Hz Input current 9 A rms max. Power factor >0.9 Unit powers up automatically when connected to a powered analyzer. Isolating switch provided |
||||||||
Measurement Connections | 2-terminals measurement via M8 studs. 4-terminal measurement via Kelvin leads and M8 studs. Measurement terminals internally protected by 1.6A fuses against normal inductor back-EMF or accidental disconnection of inductor. Front panel fuses easily replaced. |
Measurement Function | In impedance mode: L, Z, R, Q, D. Not applicable to Rdc, or transformer measurements |
|||||||||
Frequency Range | 3255BL 20 Hz to 200 kHz (not compatible with 3265B/25A and 3265BQ/25A) 3255B 20 Hz to 500 kHz 3255BQ 20 Hz to 1 MHz 3260B 20 Hz to 3 MHz (3265BQ/25A) |
|||||||||
Compliance Voltage | Maximum compliance votage (<12 kHz) 11 V DC at 0.25 V AC drive level. 10 V compliance at 1 V AC drive level. For f>12 kHz deduct 0.5 V. |
|||||||||
Basic Accuracyy | ±1%, Varies with measurement speed, frequency and options chosen. | |||||||||
Measurement Speeds | <td style="box-sizing: b | |||||||||
Input Specification | Universal 90 to 255 V AC, 47 to 63 Hz Input current 9 A rms max. Power factor >0.9 Unit powers up automatically when connected to a powered analyzer. Isolating switch provided |
|||||||||
Measurement Connections | 2-terminals measurement via M8 studs. 4-terminal measurement via Kelvin leads and M8 studs. Measurement terminals internally protected by 1.6A fuses against normal inductor back-EMF or accidental disconnection of inductor. Front panel fuses easily replaced. |
1EVA40150
켈빈 클립, 40150은 4300 시리즈 LCR 미터와 함께 사용하기위한 1EVA40100 Fine Jaw 켈빈 클립의 가격에 민감한 버전입니다.
1J1015
2 단자 125A 고정 장치, 1J1015 기존 본체 2 단자 고전류 고정 장치는 Wayne Kerr Analyzer (3255B 또는 3260B) 및 DC 바이어스 장치 (3265B) 시스템을 테스트중인 기존 본체 장치에 연결하고 최대 125A를 전달하는 데 사용됩니다. DC 바이어스 전류.
1J1036
2 터미널 기존 고정 장치, 200A 바이어스 전류를 취할 수있는 2 터미널 기본 고정 장치. 3260 + 3265 시스템에서만 사용할 수 있습니다.
3260B 시리즈
Precision Magnetics Analyzer, 8 개의 전면 패널 BNC를 사용하여 진정한 4 단자 1 차 ~ 2 차 파라미터를 포함하여 최대 3MHz의 자기 컴포넌트 분석에 필요한 모든 측정 파라미터를 제공합니다.
3255B 시리즈
Precision Magnetics Analyzer, 매우 다재다능하고 정확한 인덕턴스 분석기로 장치를 명확하고 간단한 방식으로 특성화 할 수 있습니다